Ultraviolet (UV) water purification system is a quick and effective method to disinfect water for human consumption without the need of chemicals. It is used to inactivate chlorine-resistant parasites such as Cryptosporidium and Giardia, harmful bacteria like E.Coli, and viruses not visible to the naked eye. Easy to maintain and service, systems are built with a durable stainless steel chamber to prolong life and eliminate ultraviolet light degradation.
Viqua UV: Simple units for up to 3.5 GPM
• Power supply features a lamp-on and LED power indicator
• Safety-Loc™ connector with interlock ensures power is disconnected before lamp can be removed
• High-performance lamp (9000 hours life)
VT1
Flow Rate (30mJ/cm2) | 1 GPM |
Connection | ⅜-½” MNPT |
Lamp | S212RL |
Quartz | QS-212 |
Controller | BA-VT |
Chamber | 304 SS |
Dimensions | 12.5″ x 2.5″ |
Weight | 4 lbs. |
Power consumption | 13 W |
Power supply | 100-130 V |
More Information | DATA SHEET |
VT4
Flow Rate (30mJ/cm2) | 3.5 GPM |
Connection | ½” MNPT |
Lamp | S330RL |
Quartz | QS-330 |
Controller | BA-VT |
Chamber | 304 SS |
Dimensions | 17″ x 2.5″ |
Weight | 6.5 lbs. |
Power consumption | 20 W |
Power supply | 100-130 V |
More Information | DATA SHEET |
Units with controller for up to 34 GPM
• A reliable, economical, and chemical-free way to safeguard drinking water
• Controller with audible lamp replacement reminder and countdown timer (digital display) – Lamp failure alarm
• High-performance lamp (9000 hours life)
S2Q-PA
Flow Rate (30mJ/cm2) | 3 GPM |
Connection | ½” MNPT |
Lamp | S330RL |
Quartz | QS-330 |
Controller | BA-ICE-S |
Chamber | 304 SS |
Dimensions | 17″ x 2.5″ |
Weight | 7 lbs. |
Power consumption | 22 W |
Power supply | 100-240V 50/60Hz |
More Information | DATA SHEET |
VH150
Flow Rate (30mJ/cm2) | 5 GPM |
Connection | ¾” -1″ MNPT |
Lamp | S150RL-HO |
Quartz | QSO-150 |
Controller | BA-ICE-CL |
Chamber | 304 SS |
Dimensions | 13″ x 3.5″ |
Weight | 8 lbs. |
Power consumption | 32 W |
Power supply | 120-240V 50/60Hz |
More Information | DATA SHEET |
VH200
Flow Rate (30mJ/cm2) | 9 GPM |
Connection | ¾” -1″ MNPT |
Lamp | S200RL-HO |
Quartz | QSO-200 |
Controller | BA-ICE-CL |
Chamber | 304 SS |
Dimensions | 17.75″ x 3.5″ |
Weight | 12 lbs. |
Power consumption | 35 W |
Power supply | 120-240V 50/60Hz |
More Information | DATA SHEET |
VH410
Flow Rate (30mJ/cm2) | 18 GPM |
Connection | ¾” – 1” MNPT |
Lamp | S410RL-HO |
Quartz | QSO-410 |
Controller | BA-ICE-CL |
Chamber | 304 SS |
Dimensions | 23.5″ x 3.5″ |
Weight | 17 lbs. |
Power consumption | 60 W |
Power supply | 100-240V 50/60Hz |
More Information | DATA SHEET |
VP600
Flow Rate (30mJ/cm2) | 24 GPM |
Connection | 1” MNPT |
Lamp | S600RL-HO |
Quartz | QSO-600 |
Controller | BA-ICE-C |
Chamber | 304 SS |
Dimensions | 30.7″ x 3.5″ |
Weight | 19 lbs. |
Power consumption | 70 W |
Power supply | 100-240V 50/60Hz |
More Information | DATA SHEET |
VP950
Flow Rate (30mJ/cm2) | 34 GPM |
Connection | 1 ½” MNPT |
Lamp | S950RL-HO |
Quartz | QSO-950 |
Controller | BA-ICE-C |
Chamber | 304 SS |
Dimensions | 45″ x 3.5″ |
Weight | 29 lbs. |
Power consumption | 95 W |
Power supply | 100-240V 50/60Hz |
More Information | DATA SHEET |
Units with UV monitor for up to 34 GPM
• Controller with audible lamp replacement reminder and countdown timer (digital display) – Lamp failure alarm
• High-performance lamp (9000 hours life)
• State of the art UV sensor technology to give real-time performance monitoring
VP600M
Flow Rate (30mJ/cm2) | 24 GPM |
Connection | 1” MNPT |
Lamp | S600RL-HO |
Quartz | QSO-600 |
Ballast | BA-ICE-CM |
Sensor | 254NM-C1 |
Dimensions | 30.7″ x 3.5″ |
Weight | 19 lbs. |
Power consumption | 70 W |
Power supply | 100-240V 50/60Hz |
More Information | DATA SHEET |
VP950M
Flow Rate (30mJ/cm2) | 34 GPM |
Connection | 1 ½” MNPT |
Lamp | S950RL-HO |
Quartz | QSO-950 |
Ballast | BA-ICE-CM |
Sensor | 254NM-C1 |
Dimensions | 45″ x 3.5″ |
Weight | 29 lbs. |
Power consumption | 95 W |
Power supply | 100-240V 50/60Hz |
More Information | DATA SHEET |
High Flow multilamp UV
• Includes Control Panel with easy access to controllers; visible components and power isolation
• Controller with audible lamp replacement reminder and countdown timer (digital display) – Lamp failure alarm
• High-performance lamp (9000 hours life)
• Models with “M” on item part include UV sensor for real time performance monitoring
SHF-140
Flow Rate (30mJ/cm2) | 143 GPM |
Connection | 3” FLANGE |
Number of lamps | 4 |
Lamps | S740RL-4C |
Quartz | QS-012 |
Ballast | BA-ICE-HF |
Sensor | No sensor |
Chamber | 316 SS |
Dimensions | 34” x 6″ x 14” |
Weight | 68 lbs. |
Power consumption | 320 W |
Power supply | 100-240V 50/60Hz |
More Information | DATA SHEET |
SHF-180
Flow Rate (30mJ/cm2) | 183 GPM |
Connection | 3” FLANGE |
Number of lamps | 4 |
Lamps | S950RL-4C |
Quartz | QS-180 |
Ballast | BA-ICE-HF |
Sensor | No sensor |
Chamber | 316 SS |
Dimensions | 42.5” x 6″ x 14” |
Weight | 78 lbs. |
Power consumption | 400 W |
Power supply | 100-240V 50/60Hz |
More Information | DATA SHEET |
SHFM-290
Flow Rate (30mJ/cm2) | 290 GPM |
Connection | 4” FLANGE |
Number of lamps | 5 |
Lamps | S950RL-4C |
Quartz | QSO-950 |
Ballast | BA-ICE-HF |
Sensor | 254NM-HF |
Chamber | 316 SS |
Dimensions | 42.5” x 8″ x 147” |
Weight | 287 lbs. |
Power consumption | 550 W |
Power supply | 100-240V 50/60Hz |
More Information | DATA SHEET |
Professional UV systems for up to 80 GPM
• Controller with audible lamp replacement reminder and countdown timer (digital display). Lamp failure alarm
• Cool-Touch fan technology helps reduce chamber temperature and prevent overheating
• High performance amalgam UV lamp last up to 2 years and provides up to 4x more power compering to standard lamps
• COMM center available as an optional (displays UV dose, alarm history, lamp hours, and includes dry contact connection)
H
Item Part | 650651 |
Flow Rate (30mJ/cm2) | 45 GPM |
Connection | 1 ¼” MNPT – 1” FNPT |
Lamp | 602855 |
Quartz | 602975 |
Sensor | 650580 |
Controller | 650709-005 |
Chamber | 316L SS |
Dimensions | 31″ x 4″ |
Weight | 28 lbs. |
Power consumption | 160 W |
Power | 100-240V 50/60Hz |
More Information | DATA SHEET |
K
Item Part | 660001-R |
Flow Rate (30mJ/cm2) | 80 GPM |
Connection | 2” MNPT |
Lamp | 602856 |
Quartz | 602976 |
Sensor | 650580 |
Controller | 660019-R |
Chamber | 316L SS |
Dimensions | 41″ x 4″ |
Weight | 31 lbs. |
Power consumption | 230 W |
Power | 100-240V 50/60Hz |
More Information | DATA SHEET |
Professional UV with interactive
LCD display and UV sensor
• Controller with audible lamp replacement reminder and countdown timer (digital display). Lamp failure alarm
• Cool-Touch fan technology helps reduce chamber temperature and prevent overheating on H+ and K+
• High performance amalgam UV lamp last up to 2 years and provides up to 4x more power compering to standard lamps
• UV sensor technology ensures appropriate UV Transmittance (UVT) at all times
• Interactive LCD display:
– Simultaneously displays UV Intensity status, lamp life remaining, support contact information
– Dealer-programmable support screen: load company logo and complete contact information
– Quick-reference instructions for system troubleshooting
– Pre-programmed replacement part menu
– Multi-language support:
• COMM center available as an optional (displays UV dose, alarm history, lamp hours, and includes dry contact connection), and can monitor up to 9 UV systems (up to 270 GPM!)
D4+
Item Part | 650695-R |
Flow Rate (30mJ/cm2) | 12 GPM |
Connection | ¾” MNPT |
Lamp | 602805 |
Quartz | 602732 |
Sensor | 650703 |
Controller | 650733R-001 |
Chamber | 304 SS |
Dimensions | 20.5″ x 4″ |
Weight | 10 lbs. |
Power consumption | 50 W |
Power | 100-240V 50/60Hz |
More Information | DATA SHEET |
E4+
Item Part | 650683 |
Flow Rate (30mJ/cm2) | 22 GPM |
Connection | 1” NPT |
Lamp | 602806 |
Quartz | 602733 |
Sensor | 650703 |
Controller | 650733R-001 |
Chamber | 304 SS |
Dimensions | 30″ x 4″ |
Weight | 13 lbs. |
Power consumption | 83 W |
Power | 100-240V 50/60Hz |
More Information | DATA SHEET |
F4+
Item Part | 650687 |
Flow Rate (30mJ/cm2) | 36 GPM |
Connection | 1” NPT |
Lamp | 602807 |
Quartz | 602734 |
Sensor | 650703 |
Controller | 650733R-001 |
Chamber | 304 SS |
Dimensions | 44.25″ x 4″ |
Weight | 18 lbs. |
Power consumption | 130 W |
Power | 100-240V 50/60Hz |
More Information | DATA SHEET |
H+
Item Part | 650652 |
Flow Rate (30mJ/cm2) | 45 GPM |
Connection | 1 ¼” MNPT – 1” FNPT |
Lamp | 602855 |
Quartz | 602975 |
Sensor | 650580 |
Controller | 650709-005 |
Chamber | 316L SS |
Dimensions | 31″ x 4″ |
Weight | 28 lbs. |
Power consumption | 160 W |
Power | 100-240V 50/60Hz |
More Information | DATA SHEET |
K+
Item Part | 660002-R |
Flow Rate (30mJ/cm2) | 80 GPM |
Connection | 2” MNPT |
Lamp | 602856 |
Quartz | 602976 |
Sensor | 650580 |
Controller | 660019-R |
Chamber | 316L SS |
Dimensions | 41″ x 4″ |
Weight | 31 lbs. |
Power consumption | 230 W |
Power | 100-240V 50/60Hz |
More Information | DATA SHEET |