UV SYSTEMS

Ultraviolet (UV) water purification is a quick and effective method to disinfect water for human consumption; without the need to use chemicals, or boil it.

UV Systems with light alone, or in combination with other methods of providing purified water, comply with the public health regulations of the US EPA (US Environmental Protection Agency) and WHO (World Health Organization). The Water Quality Association, based in the USA, considers equipment that uses UV light as one of the most effective methods for water purification.

Residential generic UV Systems, 1 GPM

UV6/P

Flow Rate (30mJ/cm2)1 GPM
Connection¼” quick fitting
LampLAMP UV6P
QuartzN/A
ChamberPlastic
Power supply110 V / 60 Hz

UV11/W

Flow Rate (30mJ/cm2)3.5 GPM
Connection¼” quick fitting
LampLAMP UV11SS
QuartzQUARTZ UV11SS
ChamberStainless steel
Power supply110 V / 60 Hz

Logo Viqua

Viqua UV: Simple units for up to 3.5 GPM


* Power supply features a lamp-on and LED power indicator
* Safety-Loc™ connector with interlock ensures power is disconnected before lamp can be removed
* High-performance lamp (9000 hours life)

 

viqua uv

VT1

Flow Rate (30mJ/cm2)1 GPM
Connection⅜-½” MNPT
LampS212RL
QuartzQS-212
ControllerBA-VT
Chamber304 SS
Dimensions12.5″ x 2.5″
Weight4 lbs.
Power consumption13 W
Power supply100-130 V
More InformationData Sheet

VT4

Flow Rate (30mJ/cm2)3.5 GPM
Connection½” MNPT
LampS330RL
QuartzQS-330
ControllerBA-VT
Chamber304 SS
Dimensions17″ x 2.5″
Weight6.5 lbs.
Power consumption20 W
Power supply100-130 V
More InformationData Sheet

UV Radiation

It is known that the water that comes to from the public network undergoes contamination processes during transportation, pumping, storage and distribution. Due to leaks, sediment dragging and/or old pipes, it acquires undesirable characteristics in terms of smell, color, taste and the presence of substances and microorganisms that put our health at risk.

The water coming from the public network can contain microorganisms that cause diseases and that are not detected with the naked eye or by smell or taste.

Following research and scientific testing, UV radiation produced at wavelengths between 250 and 270 nanometers (UV-C or the UVC band) has been found to be extremely effective in destroying many species of bacteria, mold spores, viruses, and other microorganisms.

Logo Viqua

Units with controller for up to 34 GPM


* A reliable, economical, and chemical-free way to safeguard drinking water
* Controller with audible lamp replacement reminder and countdown timer (digital display) – Lamp failure alarm
* High-performance lamp (9000 hours life)

 

uv water purification

S2Q-PA

Flow Rate (30mJ/cm2)3 GPM
Connection½” MNPT
LampS330RL
QuartzQS-330
ControllerBA-ICE-S
Chamber304 SS
Dimensions17″ x 2.5″
Weight7 lbs.
Power consumption22 W
Power supply100-240V 50/60Hz
More InformationData Sheet

VH150

Flow Rate (30mJ/cm2)5 GPM
Connection¾” -1" MNPT
LampS150RL-HO
QuartzQL-150
ControllerBA-ICE-CL
Chamber304 SS
Dimensions13″ x 3.5″
Weight8 lbs.
Power consumption32 W
Power supply120-240V 50/60Hz
More InformationData Sheet

VH200

Flow Rate (30mJ/cm2)9 GPM
Connection¾” -1" MNPT
LampS200RL-HO
QuartzQL-200
ControllerBA-ICE-CL
Chamber304 SS
Dimensions17.75″ x 3.5″
Weight12 lbs.
Power consumption35 W
Power supply120-240V 50/60Hz
More InformationData Sheet

VH410

Flow Rate (30mJ/cm2)18 GPM
Connection¾” – 1” MNPT
LampS410RL-HO
QuartzQS-410
ControllerBA-ICE-CL
Chamber304 SS
Dimensions23.5″ x 3.5″
Weight17 lbs.
Power consumption60 W
Power supply100-240V 50/60Hz
More InformationData Sheet

VP600

Flow Rate (30mJ/cm2)24 GPM
Connection1” MNPT
LampS600RL-HO
QuartzQSO-600
ControllerBA-ICE-C
Chamber304 SS
Dimensions30.7″ x 3.5″
Weight19 lbs.
Power consumption70 W
Power supply100-240V 50/60Hz
More InformationData Sheet

VP950

Flow Rate (30mJ/cm2)34 GPM
Connection1 ½” MNPT
LampS950RL-HO
QuartzQSO-950
ControllerBA-ICE-C
Chamber304 SS
Dimensions45″ x 3.5″
Weight29 lbs.
Power consumption95 W
Power supply100-240V 50/60Hz
More InformationData Sheet

Logo Viqua

Units with UV monitor for up to 34 GPM


* Controller with audible lamp replacement reminder and countdown timer (digital display) – Lamp failure alarm
* High-performance lamp (9000 hours life)
* State of the art UV sensor technology to give real-time performance monitoring

 

VP600M

Flow Rate (30mJ/cm2)24 GPM
Connection1” MNPT
LampS600RL-HO
QuartzQSO-600
BallastBA-ICE-CM
Sensor254NM-C1
Dimensions30.7″ x 3.5″
Weight19 lbs.
Power consumption70 W
Power supply100-240V 50/60Hz
More InformationData Sheet

VP950M

Flow Rate (30mJ/cm2)34 GPM
Connection1 ½” MNPT
LampS950RL-HO
QuartzQSO-950
BallastBA-ICE-CM
Sensor254NM-C1
Dimensions45″ x 3.5″
Weight29 lbs.
Power consumption95 W
Power supply100-240V 50/60Hz
More InformationData Sheet

Logo Viqua

High Flow multilamp UV

 

* Includes Control Panel with easy access to controllers; visible components and power isolation
* Controller with audible lamp replacement reminder and countdown timer (digital display) – Lamp failure alarm
* High-performance lamp (9000 hours life)
* Models with “M” on item part include UV sensor for real time performance monitoring

SHF-140

Flow Rate (30mJ/cm2)143 GPM
Connection3” FLANGE
Number of lamps 4
LampsS740RL-4C
QuartzQS-012
BallastBA-ICE-HF
SensorNo sensor
Chamber316 SS
Dimensions34” x 6″ x 14”
Weight68 lbs.
Power consumption320 W
Power supply100-240V 50/60Hz
More InformationData Sheet

SHF-180

Flow Rate (30mJ/cm2)183 GPM
Connection3” FLANGE
Number of lamps 4
LampsS950RL-4C
QuartzQS-180
BallastBA-ICE-HF
SensorNo sensor
Chamber316 SS
Dimensions42.5” x 6″ x 14”
Weight78 lbs.
Power consumption400 W
Power supply100-240V 50/60Hz
More InformationData Sheet

SHFM-290

Flow Rate (30mJ/cm2)290 GPM
Connection4” FLANGE
Number of lamps 5
LampsS950RL-4C
QuartzQSO-950
BallastBA-ICE-HF
Sensor254NM-HF
Chamber316 SS
Dimensions42.5” x 8″ x 147”
Weight287 lbs.
Power consumption550 W
Power supply100-240V 50/60Hz
More InformationData Sheet

Logo Viqua

Professional UV systems for up to 80 GPM

 

* Controller with audible lamp replacement reminder and countdown timer (digital display). Lamp failure alarm
* Cool-Touch fan technology helps reduce chamber temperature and prevent overheating
* High performance amalgam UV lamp last up to 2 years and provides up to 4x more power compering to standard lamps
* COMM center available as an optional (displays UV dose, alarm history, lamp hours, and includes dry contact connection)

H

Item Part650651
Flow Rate (30mJ/cm2)45 GPM
Connection1 ¼” MNPT – 1” FNPT
Lamp602855
Quartz602975
Sensor650580
Controller650709-005
Chamber316L SS
Dimensions31″ x 4″
Weight28 lbs.
Power consumption160 W
Power100-240V 50/60Hz
More InformationData Sheet

K

Item Part660001-R
Flow Rate (30mJ/cm2)80 GPM
Connection2” MNPT
Lamp602856
Quartz602976
Sensor650580
Controller660019-R
Chamber316L SS
Dimensions41″ x 4″
Weight31 lbs.
Power consumption230 W
Power100-240V 50/60Hz
More InformationData Sheet

Logo Viqua

Professional UV with interactive
LCD display and UV sensor

 

* Controller with audible lamp replacement reminder and countdown timer (digital display). Lamp failure alarm
* Cool-Touch fan technology helps reduce chamber temperature and prevent overheating on H+ and K+
* High performance amalgam UV lamp last up to 2 years and provides up to 4x more power compering to standard lamps
* UV sensor technology ensures appropriate UV Transmittance (UVT) at all times
* Interactive LCD display:

– Simultaneously displays UV Intensity status, lamp life remaining, support contact information
– Dealer-programmable support screen: load company logo and complete contact information
– Quick-reference instructions for system troubleshooting
– Pre-programmed replacement part menu
– Multi-language support:

* COMM center available as an optional (displays UV dose, alarm history, lamp hours, and includes dry contact connection), and can monitor up to 9 UV systems (up to 270 GPM!)

D4+

Item Part605695-R
Flow Rate (30mJ/cm2)12 GPM
Connection¾” MNPT
Lamp602805
Quartz602732
Sensor650703
Controller650733R-001
Chamber304 SS
Dimensions20.5″ x 4″
Weight10 lbs.
Power consumption50 W
Power100-240V 50/60Hz
More InformationData Sheet
uv light filter

E4+

Item Part650683
Flow Rate (30mJ/cm2)22 GPM
Connection1” NPT
Lamp602806
Quartz602733
Sensor650703
Controller650733R-001
Chamber304 SS
Dimensions30″ x 4″
Weight13 lbs.
Power consumption83 W
Power100-240V 50/60Hz
More InformationData Sheet

F4+

Item Part650687
Flow Rate (30mJ/cm2)36 GPM
Connection1” NPT
Lamp602807
Quartz602734
Sensor650703
Controller650733R-001
Chamber304 SS
Dimensions44.25″ x 4″
Weight18 lbs.
Power consumption130 W
Power100-240V 50/60Hz
More InformationData Sheet

H+

Item Part650652
Flow Rate (30mJ/cm2)45 GPM
Connection1 ¼” MNPT – 1” FNPT
Lamp602855
Quartz602975
Sensor650580
Controller650709-005
Chamber316L SS
Dimensions31″ x 4″
Weight28 lbs.
Power consumption160 W
Power100-240V 50/60Hz
More InformationData Sheet

K+

Item Part660002-R
Flow Rate (30mJ/cm2)80 GPM
Connection2” MNPT
Lamp602856
Quartz602976
Sensor650580
Controller660019-R
Chamber316L SS
Dimensions41″ x 4″
Weight31 lbs.
Power consumption230 W
Power100-240V 50/60Hz
More InformationData Sheet
asd