Español
Myron 720 Series II pH / ORP Monitor / Controllers

Myron 720 Series II pH / ORP Monitor / Controllers

Brand: Myron

  • Temperature Compensation: Integral temperature sensor provides automatic TC to 25°C between 0 – 100°C/ 32 – 212°F.
  • Pressure/Temperature Limits: P72S: Intermittent use up to 50 psi/690 kPa 100°C/212°F. High Temperature models available, see pH/ORP Sensor Selection Guide.
  • Cable: 5 wire, 24 ga. shielded, 10 ft./3 meters standard. 25 and 100 ft./8 and 30 meter lengths available.
  • Material: 1/2″ MNPT: CPVC body. 3/4″ MNPT: Ryton®* body.
  • Dimensions: P72S typical: overall length 165 mm/6.5 in., body 127 mm/5 in., electrode length 19 mm/.75 in.
  • *Ryton® PPS is a registered trademark of Chevron Phillips Chemical Company LLC

Prices are quoted by phone or email, the same business day.

Data sheets

Specifications

Ranges0-14 pH or ±2000 mV ORP
DisplayAnalog Models: 2.5 in./63 mm meter
Digital Models: .5 in./13 mm 3½ Digit LCD
Digital Option: 3½ Digit Backlit
LinearityElectronics: ±0.05% (±0.01 pH units/±1 mV of full scale)
ResolutionAnalog Meter: ±0.13 pH units/±40 mV
Digital Display: ±0.01 pH units/±1 mV
Sensitivity0.05% of full scale (0.01 pH units/1.0 mV)
Stability±0.05% of full scale (±0.01 pH units/±1.0 mV)
Repeatability±0.05% of full scale (±0.01 pH units/±1.0 mV)
Calibration CheckBuilt-in (7 and 0 pH / 0 and -2000 mV)
Recorder OutputIsolated 0-10 VDC @ 5 mA max. (linear); standard all models 100Ω
Output Impedance100Ω ±5%
Sensor Inputs1; 3 input option available.
(pH & ORP sensors may NOT be mixed.)
Control FunctionSingle Alarm/controller fully adjustable 0-100% of full scale
Hysteresis: Adjustable from 0.3-3% of full scale
Indicators: Above (red) and below (green) set point LEDs (reversible)
Contact Rating: SPDT 10 amp @ 125 VAC, 30 VDC
Relay operates increasing or decreasing reading (selectable)
Second Alarm/controller, with above specifications – optional
Solid State OutputPowered; 24 VDC unregulated 30 mA max.
Power115/230 VAC, 50/60 Hz, ±15% (user selectable)
24 VAC optional
Maximum Power Consumption@ 115V: 100 milliamps
Dimensions152 H x 122 W x 96 D mm / 6 H x 4.8 W x 3.8 D in.
ConstructionFully gasketed, heavy-duty ABS case; water resistant and corrosion proof IP65/NEMA 4X rated
Ambient Temp Range0-60°C / 32-140°F
Weight0,9 kg/2 lbs.

More in Monitors & Testers

See all Monitors & Testers
  • 750 Series II Conductivity / TDS Monitor / Controllers

    Myron

    Temperature Compensation: Integral thermistors provide automatic TC to 25ºC between 0-100ºC/32-212ºF. Pressure /Temperature Limits: CS51: 100 psi /…

  • 750 Series II Resistivity Monitor / Controllers

    Myron

    Constant: 0.05. Temperature Compensation: Two integral temperature sensors provide automatic TC to 25ºC. Pressure/Temp Limits: 100 psi/690 kPa @…

  • 900 Series Multi-Parameter Monitor/Controller™

    Myron

    Ranges: 0 µS – 200 mS / 0 ppm – 200 ppt / 10 KΩ – 40 MΩ / 0 – 14 pH / ±2000 mV / 0 – 250˚C · Accuracy: ± 1% of reading / ± 0.01 pH / ± 2 mV / ±…

  • Agri-Meters™

    Myron

    Conductivity Range:: 0-5 millimhos · pH Range:: 2-12 pH (AG6/PH only) · Accuracy:: pH: ±0.2 pH units Conductivity: ±2% of full scale

Need a price or help choosing a part?

Tell us the part number or what you are trying to fix. We answer in English and Spanish and ship the same day from Pembroke Park, Florida.