Myron Digital Dialysate Meter™ D-4 & D-6
Brand: Myron
Prices are quoted by phone or email, the same business day.

Brand: Myron
Prices are quoted by phone or email, the same business day.
| Display: 4 Digit LCD |
|---|
| Dimensions (LxWxH): 196 x 68 x 64 mm/7.7 x 2.7 x 2.5 in. |
| Weight: 352 g/12.4 oz. |
| Case Material: VALOX®* |
| Cond/Res/TDS Cell Material: VALOX®* |
| Cond/TDS Electrodes (4): 316 Stainless Steel |
| Cond/Res/TDS Cell Capacity: 5 ml/0.2 oz. |
| pH/ORP Sensor Well Capacity: 1,2 ml/0.04 oz. (D-6) |
| Power: 9V Alkaline Battery |
| Battery Life: >100 Hours/5000 Readings |
| Operating/Storage Temperature: 0-55°C/32-131°F |
| Protection Ratings: IP67/NEMA 6 (waterproof to 1 meter/3 feet) |
| Chemical Resistance: Resistant to hydrocarbons, dilute acids and bases, detergents, and aqueous salt solutions |
| EMI/EMC Ratings (Conformité Européenne): IEC 61326-1: 2020; CISPR 11: 2015 +A1: 2016 +A2: 2019; IEC 61000-4-2: 2008; IEC 61000-4-3: 2010; IEC 61000-4-8: 2009; (EU) 2015/863 (RoHS3): +(EU) 2024/232 |
| Flammability: PCB: UL94, V.0; Case: HB/1.47 or better |
| Conductivity | Range: 0–9999 μS/cm; 10–200 mS/cm; in 5 autoranges |
|---|---|
| Resolution: 0.01(<100 μS); 0.1(<1000 μS); 1.0(<10 mS); 0.01(<100 mS); 0.1(<200 mS) | |
| Accuracy: ±1% of reading | |
| Auto Temperature Compensation: 0–71°C / 32–160°F | |
| Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl | |
| TDS | Range: 0–9999 ppm; 10–200 ppt; in 5 autoranges |
| Resolution: 0.01(<100 ppm); 0.1(<1000 ppm); 1.0(<10 ppt); 0.01(<100 ppt); 0.1(<200 ppt) | |
| Accuracy: ±1% of reading | |
| Auto Temperature Compensation: 0–71°C / 32–160°F | |
| Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl | |
| Resistivity | Range: 10KΩ–30MΩ |
| Resolution: 0.01(<100 KΩ); 0.1(<1000 KΩ); 0.1(>1 MΩ) | |
| Accuracy: ±1% of reading | |
| Auto Temperature Compensation: 0–71°C / 32–160°F | |
| pH (D-6) | Range: 0–14 pH |
| Resolution: 0.01 pH | |
| Accuracy**: ±0.01 pH | |
| Auto Temperature Compensation: 0–71°C / 32–160°F | |
| ORP (D-6) | Range: ±999 mV |
| Resolution: 1mV | |
| Accuracy**: ±1 mV | |
| Free Chlorine FCE™ (D-6) | Range: 0.2–9.99 ppm when 350≤ORPmV<725 and 0.0≤pH<9.9 and when 725≤ORPmV<825 and 0.0≤pH<8.9 |
| Resolution: 0.01ppm | |
| Accuracy**: <1.00 ppm ±0.3 ppm; ≥1.00 ppm ±0.2 ppm | |
| Temperature | Range: 0–71°C / 32–160°F |
| Resolution: 0.1°C/F | |
| Accuracy: ±0.1°C |

Myron
Temperature Compensation: Integral temperature sensor provides automatic TC to 25°C between 0 – 100°C/ 32 – 212°F. Pressure/Temperature Limits…

Myron
Temperature Compensation: Integral thermistors provide automatic TC to 25ºC between 0-100ºC/32-212ºF. Pressure /Temperature Limits: CS51: 100 psi /…

Myron
Constant: 0.05. Temperature Compensation: Two integral temperature sensors provide automatic TC to 25ºC. Pressure/Temp Limits: 100 psi/690 kPa @…

Myron
Ranges: 0 µS – 200 mS / 0 ppm – 200 ppt / 10 KΩ – 40 MΩ / 0 – 14 pH / ±2000 mV / 0 – 250˚C · Accuracy: ± 1% of reading / ± 0.01 pH / ± 2 mV / ±…
Tell us the part number or what you are trying to fix. We answer in English and Spanish and ship the same day from Pembroke Park, Florida.